Lightolier voeding LOT Series Handleiding

PDF Handleidingen
2 Pagina's Nederlands

Lightolier voeding LOT Series
Pagina's
VAN
2
k
VA 5.0 7.5-10
W
idth (A) 36” 36”
D
epth (B) 24” 24”
H
eight (C) 80” 80”
W
idth (D) N/A 29”
Operates incandescent, magnetic and electronic ballast fluorescent, high power factor compact fluorescent, and high intensity discharge (HID) lamp types.
How to Specify:
LOT Series Uninterruptible Power Supplies LOT
Page 1 of 2 5 kVA - 10 kVA Single Phase UPS System
J
ob Inf
ormation Type:
J
ob Name:
Cat. No.:
Lamp(s):
Notes:
Lightolier a Genlyte Company
www
.lightolier
.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
W
e r
eser
ve the right to change details of design, materials and finish.
© 2006 Genlyte Gr
oup LLC (Lightolier Division) • A0406
Overall Characteristics
87% throughput efficiency, 85% emergency efficiency
Operating temperature range 32°F (0°C) to 104°F (40°C)
Fault current rating 42kAIC
Audible noise less than 50dB at 3 ft on “A” weighted scale
Automatic low battery voltage disconnect
Electrical
Sine Wave Output
Double conversion, no inter
r
uption
Voltage regulation ±2%
Fr
equency r
egulation - synchr
onized to utility
, fr
ee r
unning 60 Hz,
±
0.5%
Output voltage distortion maximum 3% THD with linear load
Load power factor capability 0.7 lead to 0.7 lag
Overload capacity 125% for 10 seconds
Input power factor correcting to 0.99
Frequency range 60Hz, ±2.5%
Input har
monic cur
r
ent distortion <5% THD
UL 1449, ANSI,IEEE C62, 41 sur
ge suppression
Completely solid-state Pulse Width Modulation (PWM) inverter
Inter
nal, make befor
e br
eak maintenance by-pass
Standar
d, UL 924 compliant, 90 minute batter
y backup
UL 924 auxiliary equipment 10 and 20 minute backup available
Microprocessor control and diagnostic system
LCD readout system status panel
Local 25 even logging/display
User pr
ogrammable automatic testing
Load integrity testing
Fault annunciating audible alarm
Cur
r
ent limiting star
t sequence
Optional output cir
cuit br
eakers (OCB) and cir
cuit breakers with trip alarm (OCBA)
Optional normally off load (NOL) energizes only during power outage, normally off
load with time delay (TDT) also available
Housing
Free standing, NEMA 1 enclosure
Seismic anchoring compatible
Lockable control access panel
Applications
The solid-state Pulse Width Modulated (PWM) inverter offers enhanced load
compatibility
Provides conditioned, uninterruptible power for other types of critical loads.
Consult factory for non-lighting load applications.
LOT
SERIES
I
NPUT OUTPUT UNIT BACK-UP NOL OUTPUT # ON 2ND # OF NOL NOL # OF NOL
VOLTAGE VOLTAGE SIZE DURATION CKT BRKRS VOLTAGE CKT BRKRS VOLTAGE 2nd VOLTAGE
L
OT = Single
P
hase
Uninterruptible
P
ower
Supplies
5
.0 = 5.0 kVA
7.5 = 7.5 kVA
10.0 = 10.0 kVA
A
= 120 V*
G
= 120/240V
J = 277 V
L = 120/208V
0
= None
1 = Yes
T = NOL w/ TDT
0
0X = Hardwire
01X = 1 OCB
02X = 2 OCB
03X = 3 OCB
04X = 4 OCB
:
:
20X = 20 OCB
------------------
01A = 1 OCBA
02A = 2 OCBA
03A = 3 OCBA
:
:
10A = 10 OCBA
Max. Pole
Spaces 20
0
0 = 2nd
Voltage
Hardwire or no
2nd Vo
ltage
01
02
03
:
:
19
A = 1
B = 2
C
= 3
D
= 4
E = 5
F
= 6
G = 7
H = 8
I = 9
J = 10
K = 11
L = 12
M = 13
N = 14
O = 15
P = 16
Q = 17
R = 18
S = 19
T = 20
Z = No NOL
1
= First
2 = Second
3 = Both
0 = No NOL
A = 1
B = 2
C
= 3
D
= 4
E = 5
F
= 6
G = 7
H = 8
I = 9
J = 10
K = 11
L = 12
M = 13
N = 14
O = 15
P = 16
Q = 17
R = 18
S = 19
Z = No NOL
A = 120 V*
G = 120/240V
J
= 277 V
L = 120/208V
Y
= 120/277V
S = 90 min
X = 10 min
Y = 20 min
(A)
(
B)
(
C)
Electronics
Cabinet
(D)
Battery
Cabinet
* Not available on 7.5 and 10.0 kVA
Gerelateerde Handleidingen voor Lightolier voeding LOT Series